
syngo.via MI VB70 What's New Online Training
In this MI what's new online training, you will learn about the new features and functionalities between software version VB60 and VB70 in syngo.via.
Continue Continue Button Continue Continue syngo.via MI VB70 What's New Online Training Master Template HILS2218 | Effective Date: 29-Jul-2021 ? syngo.via MI VB70 What’s New Online Training This online training will cover the learning content which it is necessary to know when upgrading your syngo.via system to version VB70. The online training covers Molecular Imaging and Nuclear Medicine (PET and SPECT). Learn more about the workflow consolidation to MI General Learn more about general changes a cross all syngo .via workflows Become familiar with the 4D Data Support in Volume Layouts Get to know MI Analysis applications hosted through the Digital Marketplace 1 4 3 2 Welcome audf_sv_vb70_delta_olt_mi_welcome.mp3 Audio: Welcome to the syngo.via Molecular Imaging VB70 What’s New Online Training. This online training will cover the learning content which it is necessary to know when upgrading your syngo.via system to version VB70. The online training covers Molecular Imaging and Nuclear Medicine (PET and SPECT). For navigation help, select the question mark button located in the lower right corner of each slide. ? Navigation Hints Before you start, we would like to give you a few tips on how to navigate: Table with 2 columns and 4 rows Not all pages contain audio. Some pages invite you to read for yourself or watch a video. All pages show a ? button in the lower right corner. Select the ? button to get a quick guide through the navigation elements. Some pages show an X button in the upper right corner. Select the X button to return to the overview page and not miss any information provided. Enjoy the course! ? Navigation Hints ? Workflow Consolidation to MI General – Introduction This training section will provide you with information about the consolidation of the MI Cardiology and MI Neurology workflows to MI General. The consolidation covers the following topics: Removed MI Cardiology and MI Neurology workflows and their references Retained functionality from these workflows now available in the MI General workflow Configuration state after the upgrade Move the mouse pointer over the colored callouts in the image to view the assigned workflow. Workflow Consolidation to MI General – Introduction audf_sv_vb70_delta_olt_mi_wf-consolidation_intro.mp3 Audio: The MI General workflow covers most of your MI clinical routines since it is intended for quantitative and qualitative image interpretation of NM, SPECT, SPECT/CT, PET/CT and PET/MR procedures. This training section will provide you with information about the consolidation of the MI Cardiology and MI Neurology workflows to MI General. The consolidation covers the following topics: - Information about the removed MI Cardiology and MI Neurology workflows and their references. - Information about the retained functionality from these workflows which is now available in the MI General workflow, and the configuration state after the upgrade. You will learn more about these topics in the following sections. Move the mouse pointer over the colored callouts in the image to view the assigned workflow. MI General workflow ? Workflow Consolidation – Overview Select the tab arrows to learn about the workflow consolidation. Please watch the MI General Layout Management VB50 Video and the MI VB60 Workflows Delta Online Training on PEPconnect to find out more about the extended handling capabilities of the MI General workflow. Removed Workflows and Their References Retained Functionality in MI General Configuration After the Upgrade Workflow Consolidation – Overview audf_sv_vb70_delta_olt_mi_wf-consolidation_ov.mp3 Audio Base Layer: Select the tab arrows to learn about the removed workflows and their references, the retained functionality in MI General, and the configurations after the upgrade. Please watch the "MI General - Layout Management VB50 Video” and the “MI VB60 Workflows Delta Online Training” on PEPconnect to find out more about the extended handling capabilities of the MI General workflow. audf_sv_vb70_delta_olt_mi_wf-consolidation_tab1.mp3 Audio Tab 1: To establish the workflow consolidation in MI General, the MI Cardiology and Neurology workflows and their references have been removed. The following references are affected: - The workflow assignment and batch assignment. - Any saved worklist assignments that refer to MI Cardiology or MI Neurology (e.g., Open with, View as Read only with, and the worklist filters). - The Patient Browser context menu and menu icons, and the Reporting Configuration dialog from the Configuration Panel. Select the tabs to view the workflow assignment list before and after the upgrade. audf_sv_vb70_delta_olt_mi_wf-consolidation_tab2.mp3 Audio Tab 2: Following the software upgrade to syngo.via VB70, you will find that the functionalities from the MI Cardiology and MI Neurology workflows have been retained in the MI General workflow. The tools Cardiac Planes, Cardiac Mask, and Brain AC-PC reorientation are still available in the Favorite Tools of MI General. Your user-specific worklists defined for “Workflow” or “Workflow Description” of MI Cardiology or MI Neurology are retained in MI General. Your user-specific layouts, protocols, and presets are also retained in the MI General workflow and a new AC-NAC Compare layout has been added to the Layout Gallery. Select the markers on the left to learn more about the retained functionality in MI General. audf_sv_vb70_delta_olt_mi_wf-consolidation_tab3.mp3 Audio Tab 3: Some manual configurations might be necessary after the upgrade: Workflow mapping rules which were previously mapped to MI Cardiology or MI Neurology will need to be manually remapped to MI General. If advanced mapping rules have been created for MI Cardiology and MI Neurology before the upgrade, these need to be created again and mapped to MI General. Please manually add your user-specific tools again to your Favorite Tools panel, as user-specific Favorite Tools cannot be migrated to the MI General workflow. Select the tabs to view the workflow mapping configuration before and after the upgrade. After Before Before After Configuration After the Upgrade Some manual configurations might be necessary after the upgrade: Workflow mapping rules previously mapped to MI Cardiology or MI Neurology will need to be manually remapped to MI General. Advanced mapping rules created before the upgrade will need to be created and mapped to MI General. User-specific Favorite Tools will not be migrated to the MI General workflow. These will need to be manually added after the upgrade as well. Select the tabs to view the workflow mapping configuration before and after the upgrade. Before Before After After Retained Functionality in MI General The functionality from MI Cardiology and MI Neurology has been retained in the MI General workflow. Cardiology and Neurology tools are still available in MI General User-specific worklists defined for Workflow or Workflow Description of MI Cardiology or MI Neurology are retained for MI General User-specific layouts, protocols and presets are retained in the MI General workflow A new AC-NAC Compare layout has been added to the Layout Gallery Select the markers on the left to learn more about the retained functionality in MI General. MI General workflow Available tools in the Favorite Tools panel: Brain AC-PC Cardiac Planes Cardiac Mask Layout Gallery: new AC-NAC Compare layout Removed Workflows and Their References The MI Cardiology and MI Neurology workflows and their references have been removed. Affected references: Workflow assignment and batch assignment Any saved worklist assignments that refer to MI Cardiology or MI Neurology (e.g., Open with, View as Read-Only with, worklist filters) Patient Browser context menu and menu icons Reporting Configuration dialog from the Configuration Panel Select the tabs to view the workflow assignment list before and after the upgrade. Before Before After After ? Analysis Applications Hosted Through the Digital Marketplace – Introduction * The number of applications available to you depends on your product license. Please contact your local Siemens Healthineers representative to purchase a license. All cardiology and neurology analysis applications* are now hosted through the Digital Marketplace. The following applications are available through OpenApps: Corridor4DM Cedars-Sinai Cardiac Suite syngo MBF MI Neuro DB Comparison MI Neuro Cortical Analysis MI Neuro Striatal Analysis MI Neuro Subtraction Analysis Applications Hosted in the Digital Marketplace – Introduction audf_sv_vb70_delta_olt_mi_digitalmarketplace_intro.mp3 Audio: All cardiology and neurology analysis applications relevant for Molecular Imaging are now hosted through the Digital Marketplace. In this training section, you will learn about the syngo.via OpenApps infrastructure that allows you to access the analysis applications and enables you to browse, download and test applications from Siemens Healthineers and reseller third-party applications via the Digital Marketplace. A syngo.via OpenApps User Guide Job Aid is provided via the Digital Marketplace and PEPconnect. You will learn more about these topics in the following sections. ? Analysis Applications Hosted Through the Digital Marketplace – Overview Select the tab arrows to learn how to access and handle the analysis applications. Please watch the Accessing Cardiology and Neurology Applications via OpenApps Video on PEPconnect to find out more about the handling capabilities. Accessing Cardiology and Neurology Applications Accessing the Analysis Applications with OpenApps Reload Newly Arrived Data Accessing the Analysis Applications With the Patient Browser Launching Applications in Single and Dual-Monitor Setup Analysis Applications – Overview audf_sv_vb70_delta_olt_mi_digitalmarketplace_ov.mp3 Audio Base Layer: Select the tab arrows to learn about how to access and handle the analysis applications. Please watch the "Accessing Cardiology and Neurology Applications via OpenApps Video“ on PEPconnect to find out more about the handling capabilities. audf_sv_vb70_delta_olt_mi_digitalmarketplace_tab1.mp3 Audio Tab 1: Flexible launch options are provided to launch the installed applications. You can open the analysis applications with the OpenApps tool available in the Tool Gallery or from the Favorite Tools in MI General, or directly from the Patient Browser, with limited write access (View as read-only with). Multiple applications can be opened simultaneously, and snapshots taken in any application are sent as Secondary Capture images to the Series panel. If you do not have a license for any analysis application, a trial version for these applications can be ordered and directly downloaded from the Digital Marketplace for 90 days. These applications and their respective options can be purchased as per the usual ordering process. Please contact your Siemens Healthineers representative. audf_sv_vb70_delta_olt_mi_digitalmarketplace_tab2.mp3 Audio Tab 2: To access your applications in MI General, click the OpenApps icon in the Tools Gallery or from your Favorite Tools. The OpenApps section is then displayed in the Viewing panel. An additional application panel opens, displaying all the installed applications available. The applications that are not applicable for the currently loaded images are dimmed. Select the required series you would like to use in the preview window or choose “All Data” from the Data Selection list. Click your desired application to launch the application. In the OpenApps tab, you can easily navigate between the different applications and back to MI General. Simply click the App Home icon and select another application. Or open multiple applications for the same study to toggle between the applications. audf_sv_vb70_delta_olt_mi_digitalmarketplace_tab3.mp3 Audio Tab 3: Data loaded into MI General appears listed in the syngo.via Series panel: However you cannot use the Series panel drag and drop to change the data within the OpenApps applications. If relevant data becomes available after you have opened your analysis application with the OpenApps tool, a message appears on-screen to tell you that new data for this patient is available in the system. This new data is not automatically sent to the applications launched in OpenApps, so you may need to relaunch the relevant application to use this new data. Simply click the App Home button and open your application again. The data is now available in the application. audf_sv_vb70_delta_olt_mi_digitalmarketplace_tab4.mp3 Audio Tab 4: The installed applications can also be accessed just like any other workflow from the Patient Browser. To do so, select your desired data, right-click on “Open With or View as Read-Only with” and select the application name from the workflow list. The applications open in their own patient tab, with no syngo.via elements visible (series nav., findings etc.). audf_sv_vb70_delta_olt_mi_digitalmarketplace_tab5.mp3 Audio Tab 5: The analysis applications can be launched in single and dual-monitor setup. In a single monitor setup, the applications open on the same monitor. In a dual-monitor setup, the applications open on the primary monitor by default and the app-specific help information is available on the second screen. In a dual-monitor setup, the following display-specific options are provided when you point to an application available in the apps panel: •Launch app on primary screen •Launch app on secondary screen However, you can always choose the preferred screen for launching any application. Launching Applications in Single and Dual-Monitor Setup The analysis applications can be launched in single and dual-monitor setup: In a single monitor setup, the applications open on the same monitor. In a dual-monitor setup, the applications open on the primary monitor by default and the app-specific help information is available on the second screen. In a dual-monitor setup, the following display-specific options are provided when you point to an application available in the apps panel: Launch app on primary screen Launch app on secondary screen However, you can always choose the preferred screen for launching any application. Accessing the Analysis Applications with the Patient Browser Option 2: Accessing the analysis applications from the Patient Browser Installed applications can also be accessed just like any other workflow from the Patient Browser Select the desired study Right-click on Open With or View as Read-Only with and select the application name from the workflow list The applications open in their own patient tab, with no syngo .via elements visible (series nav., findings, etc.) Reload Newly Arrived Data If relevant data becomes available after you have opened your analysis application with the OpenApps tool, a message appears on-screen to tell you that new data for this patient is available in the system. This new data is not automatically sent to the applications launched in OpenApps, so you may need to relaunch the relevant application to use this new data. Simply click the App Home button and open your application again. The data is now available in the application. Accessing the Analysis Applications With OpenApps Option 1: Accessing applications in MI General Click the OpenApps icon in the Tools Gallery or from your Favorite Tools. The OpenApps section is then displayed in the Viewing panel. An additional application panel opens, displaying all the installed applications available*. Select the required series you would like to use in the preview window (no Ctrl key needed) or choose All Data from the Data Selection list. Click your desired application to launch the application. In the OpenApps tab, you can easily navigate between the different applications and back to MI General. Simply click the App Home icon and select another application. Open multiple applications for the same study to toggle between the applications. * These applications require an optional purchase. Accessing Cardiology and Neurology Applications You can open the analysis applications* in the following ways: Option 1: With the OpenApps tool available in the Tool Gallery or from the Favorite Tools in MI General Option 2: Directly from the Patient Browser, with limited write access (View as read-only with) Multiple applications can be opened simultaneously Snapshots taken in any application are sent as Secondary Capture images to the Series panel * Availability depends on your product license(s). A 90-day trial is available. ? 4D Data Support in Volume Layouts – Introduction This training section will introduce you to the 4D data support* capability in volume layouts and in the Volume Stripe layouts for syngo.via Molecular Imaging. To find out about the full handling capabilities of 4D data support, please also watch the 4D Data Support in Volume Layouts Video. A Job Aid (PDF) MI 4D Data Support in Volume Layouts can be downloaded from PEPconnect. * This functionality is available starting from version VB60A_HF02. 4D Data Support in Volume Layouts – Introduction audf_sv_vb70_delta_olt_mi_4d-data-support_intro.mp3 Audio: This training section will introduce you to the 4D data support capability in volume layouts and in the Volume Stripe layouts for syngo.via Molecular Imaging. To find out about the full handling capabilities of 4D Data Support, please also watch the “4D Data Support in Volume Layouts Video”. A Job Aid (PDF) “MI 4D Data Support in Volume Layouts” can be downloaded from PEPconnect. Learn more about 4D data support in the following sections. ? 4D Data Support in Volume Layouts – Overview Select the tab arrows to learn more about 4D data support in Volume layouts. Display Feature Available Layouts General Data Handling 1 General Data Handling 2 4D Data Support in Volume Layouts – Overview audf_sv_vb70_delta_olt_mi_4d-data-support_ov.mp3 Audio Base Layer: Select the tab arrows to learn more about 4D data support in Volume layouts. audf_sv_vb70_delta_olt_mi_4d-data-support_tab1.mp3 Audio Tab 1: 4D data support is now added to all 3D layouts as well as to the Volume Stripe layouts. The Volume Stripe layouts are now available to support the display of 4D series (gated or dynamic). This display feature enables: 4D/4D fusion series capability for MPR/MPR and VRT/MIP image fusion. Multi-selection possibility of 4D datasets for enhanced drag and drop functionality. Show spatial changes in sequential images and temporal navigation 4D movie capability in all segments. And spatial or temporal navigation in movie mode. audf_sv_vb70_delta_olt_mi_4d-data-support_tab2.mp3 Audio Tab 2: To simplify your layout management, the 4D-only layouts have been removed from the Layout Gallery. The Volume Layouts and Volume Stripe Layouts are available in the Layout Gallery for all monitor configurations and for all MI workflows. audf_sv_vb70_delta_olt_mi_4d-data-support_tab3.mp3 Audio Tab 3: The Volume Stripe layout will automatically load the functional series. The anatomical series require drag and drop. You have the ability to drag and drop 4D datasets into Volume Layouts using the left or right mouse button. For multi-select drag and drop, two series shall be selected. Both series shall be suitable for 3D or 4D visualization and the target segment shall be 3D or 4D fusion capable. Spatial navigation can be carried out using arrow keys (gated and non-gated). Temporal navigation can be carried out using Alt + (left or right) arrow keys or by using the right mouse button and dragging left/right. audf_sv_vb70_delta_olt_mi_4d-data-support_tab4.mp3 Audio Tab 4: Please be aware of the following topics: Reset Layout from Favorite Tools is not functional for Volume Stripe. Projection data is prioritized over MIP in movie segment (Volume Stripe + movie). For PET series where no projection data is present, the movie segment will fall back to MIP. Image Fusion between two gates of the same series (same volume) is not allowed (this is applicable to all layouts – Volume Stripe and Non-Volume Stripe). The tool Auto Views is not available in Volume Stripe layouts. General Data Handling 2 General tooling in the Volume Stripe Layout: Reset Layout from Favorite Tools is not functional for Volume Stripe. Projection data is prioritized over MIP in movie segment (Volume Stripe + movie). For PET series where no projection data is present, the movie segment will fall back to MIP. Image Fusion between two gates of the same series (same volume) is not allowed (this is applicable to all layouts – Volume Stripe and Non-Volume Stripe). The tool Auto Views is not available in Volume Stripe layouts. General Data Handling 1 Volume Stripe will automatically load functional series. Anatomical series require drag and drop. Drag and drop 4D datasets into Volume Layouts using the left or right mouse button. For multi-select drag and drop, two series shall be selected: Both series shall be suitable for 3D or 4D visualization. The target segment shall be 3D or 4D fusion capable. Spatial navigation can be carried out using the arrow keys (gated and non-gated). Temporal navigation can be carried out using Alt + (left or right) arrow keys or by using the right mouse button and dragging left/right. Available Layouts To simplify your layout management, the 4D-only layouts have been removed from the Layout Gallery: The Volume Layouts are available in the Layout Gallery for all monitor configurations and for all MI workflows: Display Feature 4D data support is now added to all 3D layouts as well as to the Volume Stripe layouts. The Volume Stripe layouts are now available to support the display of 4D series (gated or dynamic). This display feature enables: 4D/4D fusion capability for MPR/MPR and VRT/MIP image fusion Multi-selection of 4D datasets for enhanced drag and drop Show spatial changes in sequential images Temporal navigation 4D movie capability in all segments Spatial or temporal navigation in movie mode ? General Changes – Introduction This training section will introduce you to the general changes which have been made across all syngo.via workflows to enhance the study reading and results: New display of studies to identify time points Change in data handling for reconstructed series Reset Layout tool now available in MI General General Changes – Introduction audf_sv_vb70_delta_olt_mi_general-changes_intro.mp3 Audio: This training section will introduce you to the general changes which have been made across all syngo.via workflows to enhance the study reading and results: This affects the new display of studies to identify studies and multi-time point studies more easily, a data handling change for reconstructed series, and an introduction to the implemented Reset Layout tool which is now available in MI General ? General Changes – Overview Select the tab arrows to learn about the general changes. Color Identification of Time Points Change in Data Handling for Reconstructions Reset Layout Tool General ChangesGeneral Changes – Overview audf_sv_vb70_delta_olt_mi_general-changes_ov.mp3 Audio Base Layer: Select the tab arrows to learn about the general changes. audf_sv_vb70_delta_olt_mi_general-changes_tab1.mp3 Audio Tab 1: To identify studies and time points more easily, the terms ‘’Current’’, ‘’Prior’’ and “Later” have been replaced with a colorized Study Date (or acquisition date if the study date is not available in the DICOM header). This is a new consistent behavior across all syngo.via workflows. The Study Date is highlighted in each segment with a larger font and the same color is used wherever that time point is shown, e.g., in the Series Navigator, Trending Graph, etc. Please refer to the “syngo.via VB70 What’s New” Job Aid to find out more about the extended handling capabilities. audf_sv_vb70_delta_olt_mi_general-changes_tab2.mp3 Audio Tab 2: To ensure consistent behavior across all syngo.via workflows, the data handling for reconstructed series has been changed. This applies to Ranges and FAST Ranges new series created. The NM reconstructions are now listed under the 2D NM Modality reconstruction bundle in the Series Navigator. The CT and Fused reconstructions are still listed under the Additional Data bundle. The Delete functionality has been removed for reconstructions in the Series Navigator. Deletion needs to be carried out after saving and closing the workflow from the Patient Browser as with all other patient data. audf_sv_vb70_delta_olt_mi_general-changes_tab3.mp3 Audio Tab 3: A Reset Layout tool is now available in MI General. Reset Layout will restore the current layout to the default initial display. The following can be reset: The drag and drop actions which have changed the series being displayed Manual or automatic orientations Changes to filter types Changes to windowing, LUTs or other properties of the display Please note: This feature currently does not work on Volume Stripe layouts Reset Layout Tool A Reset Layout tool is now available in MI General. Reset Layout will restore the current layout to the default initial display. The following can be reset: Drag and drop actions which have changed the series being displayed Manual or automatic orientations Changes to filter types Changes to windowing, LUTs or other properties of the display Please note: This feature currently does not work on Volume Stripe layouts. Change in Data Handling for Reconstructions NM reconstructions (Ranges / FAST Ranges) are now listed under the 2D NM Modality reconstruction bundle in the Series Navigator. CT and Fused reconstructions are still listed under the Additional Data bundle. Delete is removed for reconstructions in the Series Navigator. This needs to be carried out after saving and closing the workflow from the Patient Browser. NM recons Color Identification of Time Points The terms Current, Prior, and Later have been replaced by the colorized study date The color identification of time points as a consistent behavior across all syngo.via workflows Colored text also used for easy identification of studies The study date is highlighted in each segment with a larger font Same color is used wherever that time point is shown, e.g., in the Series Navigator, Trending Graph, etc. Please refer to the syngo.via VB70 What’s New Job Aid to find out more about the extended handling capabilities. Colored text for easy identification of timepoints ? Course Review Congratulations. You have completed the syngo.via MI VB70 What’s New Online Training. Select the numbered buttons below to review the material before proceeding to the final assessment. 4D Data Support in Volume Layouts MI Analysis Applications Hosted Through the Digital Marketplace Workflow Consolidation to MI General 1 1 2 2 3 3 General Changes Across all syngo.via Workflows 4 4 Course Review General Changes Across all syngo .via Workflows General changes have been made across all syngo.via workflows to enhance the study reading and results: Colorized study date: The terms Current, Prior, and Later have been replaced by the colorized study date The color identification of time points as a consistent behavior across all syngo.via workflows Colored text also used for easy identification of studies The study date is highlighted in each segment with a larger font Same color is used wherever that time point is shown, e.g., in the Series Navigator, Trending Graph, etc. Change in data handling for reconstructions: NM reconstructions (Ranges/ FAST Ranges) are now listed under the 2D NM Modality reconstruction bundle in the Series Navigator CT and Fused reconstructions are still listed under the Additional Data bundle Reset Layout tool: A Reset Layout tool is now available in MI General. Reset Layout will restore the current layout to the default initial display. 4D Data Support in Volume Layouts 4D data support is now added to all 3D layouts as well as to the Volume Stripe layouts. The Volume Stripe layouts are now available to support the display of 4D series (gated or dynamic). This display feature enables: 4D/4D fusion series capability for MPR/MPR and VRT/MIP image fusion. Multi-selection possibility of 4D data sets for the enhanced drag and drop functionality. Show spatial changes in sequential images and temporal navigation. 4D movie capability in all segments. Spatial or temporal navigation in movie mode. MI Analysis Applications Hosted Through the Digital Marketplace All Cardiology and Neurology Analysis Applications which are relevant for Molecular Imaging are now hosted through the Digital Marketplace. Analysis applications can be launched with the OpenApps button available in the Tool Gallery from the MI General workflow. An additional application panel opens, displaying all the installed applications available. Data selection is possible via the preview window (No Ctrl & left mouse button) and the Data Selection list. The App Home button is used to select another application. Newly arrived data can also be sent to the relevant application using the App Home button. You can open multiple applications for the same study to toggle between the applications. Analysis applications can also be launched directly from the Patient Browser, with RMB Open with (limited write access/View as read-only with). The applications open in their own patient tab, with no syngo.via elements visible (series nav., findings etc.). Multiple applications can be opened simultaneously. The analysis applications can be launched in single and dual-monitor setup. Snapshots taken in any application are sent as Secondary Capture images to the Series panel. Workflow Consolidation in MI General Following the software upgrade to syngo.via VB70, the functionalities from MI Cardiology and MI Neurology have been retained in the MI General workflow. The tools Cardiac Planes, Cardiac Mask and Brain AC-PC re-orientation are still available in the Favorite Tools of MI General. User-specific worklists defined for Workflow or Workflow Description of MI Cardiology or MI Neurology are retained in MI General. User-specific layouts, protocols and presets are also retained in the MI General workflow. A new AC/NAC Compare Layout has been added to the Layout Gallery. MI Cardiology and MI Neurology workflows and their references have been removed. Some manual configurations might be necessary after the upgrade : Workflow mapping rules previously mapped to MI Cardiology or MI Neurology will need to be manually re-mapped to MI General. Advanced mapping rules created before the upgrade will need to be created and mapped to MI General. User-specific Favorite Tools cannot be migrated to the MI General workflow. These will need to be manually added after the upgrade as well. Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com ? Disclaimer Assessment Start ? This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate . Assessment questions must be answered completely to receive full credit. Partial credit will not be given for assessment questions that require multiple answers. You may repeat the assessment as many times as needed. Assessment ? Select two (2) answers. Question 1 of 6 After upgrading your system, what applies to the functionality of MI Cardiology and MI Neurology? Cardiology and Neurology tools are still available in MI General. The MI Cardiology and MI Neurology workflows and their references are still available. Workflow mapping rules previously mapped to MI Cardiology or MI Neurology need to be manually remapped to MI General. Multiple Answer Incorrect One or more answers are incorrect. Correct Select the best answer. ? Question 2 of 6 Where can you launch cardiology and neurology analysis applications? Analysis applications can only be launched through the Digital Marketplace. Analysis applications can either be launched directly from the Patient Browser (by right-clicking) or with the OpenApps icon in the MI General workflow. Analysis applications can only be launched within the MI General workflow. Multiple Choice Incorrect Incorrect Incorrect Select the best answer. ? Question 3 of 6 Which layouts support the display of 4D data? Volume Stripe layouts can support the display of 4D series (gated or dynamic). MI layouts only support 2D/3D data. Only 3D layouts support 4D data. Only 4D layouts support 4D data. Multiple Choice Incorrect Incorrect Incorrect Correct Select the best answer. ? Question 4 of 6 What is true about Cardiology and Neurology Analysis Applications? The Cardiology and Neurology Analysis Applications are hosted through the Digital Marketplace. Only one application can be opened through the Digital Marketplace. The analysis applications can only be launched in single-monitor setup. Multiple Choice Incorrect Incorrect Correct Select the best answer. ? Question 5 of 6 What is true about resetting a layout? Resetting a layout is only possible in the MM Reading workflow. Resetting a layout is only possible in the MM Oncology workflow. The Reset Layout tool can only reset the manual or automatic orientations. The Reset Layout tool will restore the current layout to the default initial display. Multiple Choice Incorrect Incorrect Incorrect Correct Select the best answer. ? Question 6 of 6 What is correct about study grouping in syngo.via VB70? The time points are grouped in Current, Prior, and Later in the Series Navigator. Time points are grouped with a colorized study date in the Series Navigator. Different color is used wherever that time point is shown, e.g., Series Navigator, Trending Graph, etc. Multiple Choice Correct Incorrect Correct Assessment Results YOUR SCORE: PASSING SCORE: Review Retry Retry Continue Continue Continue %Results.ScorePercent%% %Results.PassPercent%% ? Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course.. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the syngo .via MI VB70 What’s New Online Training. Completion Untitled Scene Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Timeline Select the buttons to learn more about a topic. Be sure to review all topics before navigating to the next slide. Click Next to continue. Next Tab Arrow Slide Select the X to close the pop-up. Click Next to continue. Next Layer Slide Some images may have a magnifier icon. Select the image to see an enlarged view. Select it again to return to the normal view. Click Next to continue. Next Zoom Slide Some images have a magnifier icon in the bottom-left corner. Select these images to see an enlarged view of the image. Select the image again to return to the normal view. Select Submit to record your response. Click the X in the upper right corner to exit the navigation help. Assessment Slide Question Bank 1 HOOD05162003270742 | Effective Date: 26-APR-2022 1.1 Welcome 1.2 Navigation Hints 1.3 Workflow Consolidation to MI General – Introduction 1.4 Workflow Consolidation – Overview 1.5 Analysis Applications Hosted in the Digital Marketplace – Introduction 1.6 Analysis Applications – Overview 1.7 4D Data Support in Volume Layouts – Introduction 1.8 4D Data Support in Volume Layouts – Overview 1.9 General Changes – Introduction 1.10 General Changes – Overview 1.11 Course Review 1.12 Disclaimer 1.13 Assessment
- delta olt
- online training
- whats new