Siemens Healthineers Academy
<i>syngo</i>.via CT VB70 What's New Job Aid

syngo.via CT VB70 What's New Job Aid

This what's new job aid provides information about new features and functionalities with syngo.via VB70 in CT. It contains information about Bone Removal Improvement, Interactive Spectral Imaging, Rapid Results Technology Improvement, Features for NAEOTOM Alpha and MM Reading CT Features. Duration: 40 min.

SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid Template Effective Date: 10 Aug 2021| HILS 2223 Job Aid Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 syngo.via CT VB70 What’s New Job Aid – SIEMENS Healthineers Table of Contents Bone Removal Feature Improvement 3 Interactive Spectral Imaging in MM Oncology 6 Healthineers Extended features in Rapid Results Technology 11 Features for NAEOTOM Alpha 18 MM Reading CT Features 22 CASITEM COM • ASPECTS 22 • Interactive Spectral Imaging 25 • LungCAD 27 • Lesion Quantification 32 • Similar Patient Search (CT Lung Assistant) 34 • Cinematic Insight 37 2 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid Bone Removal Feature Improvement 3 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Bone Removal Feature Improvement* SIEMENS Healthineers The Bone Removal algorithm has been improved in Head and Neck. • The algorithm update will be visible in CT Vascular, CT View&GO part of syngo.CT Extended Functionality. * Only for single energy images 4 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Bone Removal Feature Improvement – SIEMENS Healthineers Sample Images Some parts of vessels are removed with bone. The bones are removed properly. HPR HPR AS+ NeuroDSA_Carotids_Aneurysm, NYU_USA AS+ NeuroDSA_Carotids_Aneurysm, NYU_USA 2012R0480 Ref.: Neurovascular Gold 2012R0480 *27.09.2011, O Definition AS+ Ref.: Neurovascular Gold *27.09.2011, O Definition AS+ Carotids 0.75 C+ Carotids 0.75 C+ 10.08.2011 10.08.2011 13:45:05 13:45:05 SP A309,9 SP A495,1 A. carotis | int. A. carotis r int. A. carotis | int. RAH RAH A. carotis r int. A. carotis r ext. A. carotis r ext. A. carotis | ext. A. carotis | ext 0cm 10cm Manip VRT Manip VRT KV 120 kV 120 mAs 400 mAs 400 H37f H37f LAO 26 AL LAO 35 A CRAN 8 CRAN 18 M 512x512 M 512×512 O VB60 VB70 5 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid Interactive Spectral Imaging in MM Oncology 6 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Interactive Spectral Imaging (ISI) in MM Oncology SIEMENS Healthineers • ISI is now available in MM Oncology* R Reset L4VOI1 CT 2 RECIST 1.1 Diam.: 56,1 mm Mond Max. Orth. Diam.: 44,8 mm • The ROI and CT Segmentation tools simultaneously display the keV Mono+ Volume: 51,488 ml VNC lodine Density: 0,6 mg/ml lodine Uptake: 33,0 mg mean HU value of the diagnostic CT image (e.g., Mixed, Mono+), Mixed MIX / VNC /LODINE Mean: 68,4 HU/ 46 6 HU/ 21,8 HU lodine the VNC image and the Iodine Map independently of and in addition to the chosen representation. VB70 CT Layout VB70 CTDE Layout • Replacement of Mean NMI / Mean HMI line in evaluation label with MIX or Mono+ / VNC/L_VNC / IODINE or L_IODINE. L1VON1 CT 2 Please note: No fused VNC/Iodine representation based on SPP** RECIST 1.1 Diam.: 73.2 mm Max. Orth. Diam.: 50.9 mm Volume: 116.599 ml provided via interactive image text (as it is in MM Reading and Mean NMI: -44.5/ 21.4/ 66.0 HU lodine Density: 1.7 mg/ml lodine Uptake: 203.0 mg syngo.CT extended functionality). VB60 CTDE Layout * Part of syngo.via MI Workflows 7 ** Spectral Postprocessing Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Interactive Spectral Imaging (ISI) in MM Oncology SIEMENS Healthineers New Features • An interactive image text (with on-the-fly input image generation from SSP) includes: L4VOI1 CT 2 R RECIST 1.1 Diam.: 56,1 mm Max. Orth. Diam.: 44,8 mm • A representation switch to switch image Volume: 51,488 ml Mono lodine Density: 0,6 mg/ml kev leset lodine Uptake: 33,0 mg impression. Existing measurements are preserved Mono+ MIX / VNC / IODINE VNC Mean: 68,4 HU/ 46,6 HU/ 21,8 HU after the switch. Mixed lodine • An interactive keV/ratio slider to change interactively the image impression for the Mono+ Triplet of values for ROI representation and the mixed ratio. CT Layout measurement • A triplet of values (Mixed, VNC, Iodine) for ROI measurements for measurements for Lesion Segmentation. • Replacement of NMI/HMI. 8 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Measurement Results – SIEMENS Healthineers Name and Layout The following Dual Energy information can be measured Virtual depending on the layout used: Layout Liver VNC Unenhanced Mix / L_VNC / L _ IODINE for Liver VNC DECT Liver X • DECT Liver 3D X • Mix / VNC / IODINE for Virtual Unenhanced DECT Liver 3D 2TP X • Density in mg/ml DECT Liver 4 TP X • Iodine Uptake in mg DECT X DECT 3D X DECT 3D 2TP X DECT 4TP X SPP on non-DE X (called VNC) 9 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Measurement Results – SIEMENS Healthineers Comparison of VB60 and VB70 The name of the mean value is different for Liver VNC and Virtual Unenhanced. Up to VB60 From VB70 L3VOI1 CT_2 RECIST 1.1 Diam.: 34,3 mm L9VON1 CT 2 RECIST 1.1 Diam.: 36,1 mm Max. Orth. Diam.: 22,6 mm Max. Orth. Diam.: 29,1 mm Volume: 5 987 ml Volume: 11,334 ml Liver VNC lodine Density: -0,3 mg/ml Mean HMI: -84,3/-85,9/ -1,6 HU lodine Uptake: -3,7 mg Todine Density: -0, 1 mg/ml MIX / L_VNC / L_IODINE lodine Uptake: -0,5 mg Mean: -6,8 HU/ -3.0 HU/ -4,0 HU L6VOI1 CT_2 VOI1 CT_2 RECIST 1.1 Diam.: 8,9 mm RECIST 1.1 Diam.: 28,8 mm Max. Orth. Diam.: 13,7 mm Max. Orth. Diam.: 19,0 mm Virtual Unenhanced Volume: 5,630 ml Volume: 1 888 ml lodine Density: -0,5 mg/ml Mean NMI: 37,9/ 323,2/ 282,4 HU lodine Uptake: -2,9 mg Todine Density. 8,8 mg/ml MIX / VNC / IODINE lodine Uptake: 16,6 mg Mean: 8,4 HU/ 24,7 HU/ -16,4 HU 10 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid Extended Features in Rapid Results Technology 11 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Cinematic VRT SIEMENS Healthineers Cinematic VRT* can be chosen from the Properties of Aorta Range_New1 Display Type list. Please note: Cinematic VRT will be changed Anatomical Structure Aorta to normal VRT for editing. Ranges Type Radial General Parameters Display Type Cinematic VRT VRT VRT Preset Cinematic VRT MIP Orientation Sagittal * Cinematic Volume Rendering Technique is an optional feature. 12 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Image Resolution for Cinematic Rendering SIEMENS Healthineers • Normal retains the original resolution of the image. Visualization The output depends on the image size and aspect ¥ Table Removal ratio of the FoV. Bone Removal Isolate Heart 1 • High multiplies the resolution of the results by the configured value. The default value is 2. Isolate Coronary Tree 1 Please note: Selecting High for Cinematic VRT results will Image Resolution Normal Normal multiply the time needed for computing the results by a High factor of around 4 compared to Normal. 13 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Cinematic VRT Preset SIEMENS Healthineers • More than 70 Siemens Healthineers factory default General Parameters VRT presets are available. Display Type Cinematic VRT • All VRT presets can also be used for Cinematic VRT VRT Preset Vascular Cinematic images. However, there are some specific cinematic Soft tissue Orientation presets listed, for example, Vascular Cinematic. If a Solid Solid 2 cinematic preset exists, using the cinematic presets Image Order Solid MI for Cinematic VRT is recommended. Viewing Direction Solid Shaded Spine Angle between Images Spine B/W Thorax Number of Images Thorax Aneurysm Thorax Gray Image Comment Translucent Translucent 2 Translucent MI Vascular Cinematic Vascular General 14 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Head Default Factory Protocols SIEMENS Healthineers The following protocols have been included in the factory default protocols: • A. Carotis Bifurcation L Range • A. Carotis Bifurcation R Range Choose a Result Type: Properties of A. Carotis Bifurcation L Range_New1 Head and Neck Anatomical Structure A. Carotis Bifurcation L A. Carotis Bifurcation L Range A. Carotis Bifurcation R Range Ranges Type Parallel A. Carotis COW Range A. Carotis L Int. Range General Parameters A. Carotis R Int. Range Complete Volume Range Display Type MPR Thick CT ASPECT Score CT Neuro Perfusion Windowing Preset Soft-Tissue General Alignment Range Orientation Axial Head & Neck Range Head AC-PC Line Range Image Order Head to Feet Viewing Direction Feet to Head Configure Result Image Thickness mm Distance between Images 0.7 mm Image Comment 15 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Curved Ranges Type of Spine Range SIEMENS Healthineers Image order and viewing direction can be set for Curved Ranges Type of Spine Range. Properties of Abdomen Range_New1 Properties of Complete Volume Range_New1 Anatomical Structure Anatomical Structure Spine Spine Curved Ranges Type Ranges Type Curved General Parameters General Parameters Display Type MPR Thick Display Type MPR Thick Windowing Preset Soft-Tissue Windowing Preset Soft-Tissue Orientation Sagittal Orientation Sagittal Image Order Right to Left Image Thickness Viewing Direction mm Left to Right Distance between Images 0,7 Image Thickness mm mm Distance between Images 2 mm Number of Images 60 Number of Images 60 Image Comment Image Comment VB60 VB70 16 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 General Features and Information – SIEMENS Healthineers Removal of FastTransfer FastTransfer can be configured in Somaris 5 * and Somaris 7 ** Siemens Healthcare Service Software - Internet Explorer provided by Siemens Healthcare scanners. Configuration Service Key Expiry Date: 20190211 Reports Home It is not recommended to use the FastTransfer feature due to the possibility System Options Network Workflow Specific Configuration -Local Host Export 3D Reference Image of unforeseeable problems that can appear even without notification. Site Info TCP/IP LAN Machine Prefix for Autosend on Exam End check Application Technical Single Tube Syngo FastTransfer Nodes ]PKCTE08RN Maintenance JPKCTE03RN Starting with VB70, syngo.via will ignore the FastTransfer setting, and the Users FO3CTE15W MonitorType OVIA_VB30 - Security OPKCTE02RN transfer is changed to DICOM transfer automatically. The data role is kept in -Database Syngo Via VIA_VB30 V Satellite Console the image transfer with RRT configuration. So, the images are transferred, Wake on LAN Export Topogram - Service even if FastTransfer is still configured on the CT scanner. T * SOMATOM Perspective, SOMATOM Emotion and SOMATOM Scope 17 ** SOMATOM Force, SOMATOM Drive, SOMATOM Edge Plus, SOMATOM Definition Flush, SOMATOM Definition Edge, Effective Date: 28 Sep 2022|HOOD05162003304980 SOMATOM Definition AS+ and SOMATOM Definition AS Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid Features for NAEOTOM Alpha 18 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 DE Application Class in NAEOTOM Alpha SIEMENS Healthineers Kidney Stone, Liver VNC, Gout and Lung Analysis are available as DE Application class for CT Dual Energy. Available DE Application class in NAEOTOM Alpha: • syngo.CT DE Monoenergetic Plus • syngo.CT DE VNC • syngo.CT DE Calculi Characterization* • syngo.CT DE Liver VNC without fat map* • syngo.CT DE Gout* • syngo.CT DE Lung Analysis* * Available for syngo.CT Dual Energy VB71. Not available in the US and some other countries. 19 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Pure Lumen of ISI* SIEMENS Healthineers Pure Lumen* is only available for VSPP (Vascular Spectral Postprocessing) data acquired in NAEOTOM Alpha. The calcium is subtracted from all the images so that only the lumen of the vessels remains Real lumen visible and activates the Pure Lumen image pathologic representation in all segments. wall with different Patient received stent as composites Pure Lumen is available in Interactive Spectral treatment of severe stenosis Severe degree of coronary Calcification masks Pure Lumen reveals • Imaging (ISI) of the following workflows: artery disease with the pathology and the underlying reality calcifications distortsseverity of of the pathology → Ability to guide the • CT Coronary Analysis Cardiac symptoms the stenosis • persisting → No value cardiologist with non- CT Vascular Analysis delivered invasive imaging in • advanced CAD • MM Oncology • MM Reading 20 20 Courtesy of Medical University of South Carolina, Charleston, USA * Part of the syngo.CT Extended Functionality and available with syngo.via VB60 Effective Date 28 Sep 2022|HOOD05162003304980 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Unrestricted © Siemens Healthineers, 2022 Pure Lumen – SIEMENS Healthineers Selection in ISI Pure Lumen can be chosen from the ISI In syngo.via CT Vascular Workflow and syngo.via CT context menu by right clicking or by toggling Coronary Workflow, the Remove Calcium icon is the interactive image text until Pure Lumen is displayed if the VSPP data set is loaded. The calcium displayed. removal will be available on the default DE representation. APR MPR CT Vascular SL 0,5 SI 0 5 Mon Pure Lumen key Reset -IT Mono+ Remove Bone Edit Remove Marker Table Remov. Calcium Pure Lumen Bones VNC lodine Manual Vessel SURF VNC/lodine Plane 21 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid ASPECTS MM Reading CT Features This feature is still under development and not commercially available in the US. Its future availability cannot be ensured. 22 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 ASPECT Score SIEMENS Healthineers Calculates the ASPECT Score, which allows for the detection of early ischemic changes on non-contrast CT scans of the brain. The tool allows you to edit the detected brain areas. C 34.5 C 36.1 IC 35.1 IC 35.2 INS 31.6 X INS 34.1 Alberta Stroke Program Early CT Score, L 36.4 37.5 M1 33.6 WM M1 35.6 ASPECTS, is a quantitative scoring system M2 35.3 M2 35.7 used to assess the severity and extent of M3 37.0 M3 37.3 M4 34.5 M4 35.3 early ischemic changes for patients with M5 33.2 X M5 35.1 M6 35.6 M6 35.8 middle cerebral artery stroke. ASPECT Score 7 Edit incorrect regions and confirm the results. Confirm Results Cancel This feature is still under development and not commercially available in the US. Its future availability cannot be ensured. 23 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 ASPECT Score – SIEMENS Healthineers How do we use it? • The ASPECTS button is available in the Tool Gallery. • Activate it to initiate the computation of the ASPECTS. • The overlay is displayed once the calculation has finished. 34.5 X C 36. Pathological areas are displayed in red and normal IC 35 IC 35.2 • INS 31.6 X INS 34.1 regions are contoured in yellow. L 364 37.5 M1 33.6 WM M1 35.6 M2 353 M2 35.7 • You have the option to edit the regions, by clicking in M3 37.0 M3 37.3 M4 34.5 M4 35.3 a region to toggle between a pathological/normal M5 33.2 X M5 35.1 MG 35.6 M6 35.8 region. ASPECT Score 7 • Click inside the desired region and the score is i Edit incorrect regions and adapted accordingly. confirm the results. Confirm Cancel Results • A mini toolbar is displayed at the bottom of the segment, where you can Accept or Reject the results once you have reviewed them. ASPECT Score Accept or reject the results This feature is still under development and not commercially available in the US. Its future availability cannot be ensured. 24 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid Interactive Spectral Imaging MM Reading CT Features 25 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Measurements Handling – SIEMENS Healthineers Region of Interest (ROI) • Interactive Spectral Imaging (ISI) is a simplified way of visualizing Dual Energy data. • It allows you to visualize different spectral representations by interacting with the image text, once the Spectral Post Processing series are displayed in the layout. What is new? • When performing a measurement with the ROI Isocontour, freehand or polygonal tools, the measurement details text displays the mean Hounsfield Units (HU) for MIX, VNC, Iodine. This gives you an overview of the HU (or Iodine concentration) in the other representations without the [1] ROI Polygonal Min / Max: -24-HU/58 HU need to change the representation in the image segment. Mean/SD: 17 HU/10 HU Area: 48.13 cm2 • In previous versions, this feature was only supported by the MIX / VNC / IODINE ROI circle. Mean: 17 HU/21 HU/-4 HU 26 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid LungCAD MM Reading CT Features 27 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 LungCAD – SIEMENS Healthineers Introduction • The syngo.CT LungCAD is a computer-aided detection (CAD) tool, designed to assist radiologists in the detection SL : 1 mm of solid and subsolid (part-solid and ground glass) pulmonary nodules, during the review of multi-detector computed tomography (MDCT) from multivendor examinations of the chest. R CADT. • During the reading, multiple time points are supported, C1, Change Since: 8/19/2014 which facilitates a follow-up of the LungCAD results, thus Diameter: 11 36mm (+17%)) Max. Orth. Diam: 10.82 mm (+18%) Volume; 0.58 ml (+49%) allowing for fast automatic segmentation and comparison VDT. 82 Days 8/19/2014 of the detected lung nodules. 6/10/2014 3/7/2013 Select Price 28 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 LungCAD – SIEMENS Healthineers What’s New? Two new features are available: 1. Selection of prior case Allows you to manually select a different baseline series for the B comparison of the lung nodules, thus allowing for the percentage of L change values to be computed between different study dates. Select Prior S 1/8 53 2. Adapt the lesion properties Option to configure the lesion properties to be displayed in the nodule measurement evaluation text. LungCA Lesion Properties Remove from Favorites 29 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 What’s New? – SIEMENS Healthineers Multiple Time Point Support You can change the prior case used for the baseline comparison, in order to obtain 8/19/2014 the comparison values (% of change) with a different time point. 6/10/2014 3/7/2013 B How do you use it? L 1. Ensure that the priors that you want to compare are displayed in the layout. You Select Prior 117 X can add another prior to the layout, by dragging and dropping using the right mouse button from the series panel and selecting Add as MPR or Add as 2D. 2. Select an image from the current case and activate the LungCAD tool from the Select Prior button Tool Gallery. 3. By default, the first prior study is used for the comparison. If you want to compare with, for example, the prior 02 case, select it using the Select Prior * Please note: When replacing the button available in the navigation toolbar of the LungCAD tool, as highlighted in active prior (i.e. the prior for which the image. the change values are currently 4. Please note that only the priors displayed in the layout are added to the Select being displayed), the LungCAD tool H. Prior dialog. is disabled. You need to activate it 5. If the study you want to compare is not available in the Select Prior dialog, first again in order for the Select Prior add it to the layout (by dragging and dropping using the right mouse button → dialog to be updated. select Add as MPR). The Select Prior dialog is updated automatically*. 30 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 What’s New? – SIEMENS Healthineers Lesion Properties • The LungCAD tool now provides a properties dialog that Lesion Properties ? × allows you to change the values displayed in the measurements display box. Display the following evaluations: Diameter • This has the advantage of allowing you to select only the M. Max. Orth. Diam measurements that you commonly report on. IMean Diameter WHO Area • To access the properties dialog, right click on the tool in the Volume Tool Gallery and select Lesion Properties. Min/Max HU Mean/SD HU • Adapt the displayed measurements as desired and press or M VDT click Ok. Lungc Lesion Properties Remove from Favorites Ok Cancel • These settings are saved in your user profile and are applied the next time you activate the LungCAD tool. 31 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid Lesion Quantification MM Reading CT Features 32 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Lesion Quantification Tool SIEMENS Healthineers • The Lesion Quantification tool performs a semi-automatic 3D segmentation for the quantification of lung nodules in CT datasets. The results provide useful clinical measurements like (RECIST) diameter, volume and automatic comparison values. • This tool supports a follow-up examination, displaying the percentage of change of the measurements between two time points in the measurement details box of the current case. What is new? • This tool now supports multiple time points comparison. Select Prior • It is possible to edit the Lesion Properties, in order to configure the measurement attributes displayed in the measurement details box (same as with LungCAD tool). How do you use it? • Display all the images that you want to compare in the layout. • Carry out the measurement in the current case - the corresponding lesion in the prior 01 case is automatically measured and compared. • A mini toolbar is displayed at the bottom of the segment that allows you to select a different prior case. • Please note: Only time points displayed in the layout are available in the time point navigator. 33 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid Similar Patient Search (CT Lung Assistant) MM Reading CT Features 34 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Similar Patient Search Web Services (1/2) SIEMENS Healthineers CT Lung Assistant - DummyPatName! (1/1/1960) • The Similar Patient Search (SPS) Web Service is an O x interactive tool that provides supplementary information SIEMENS Healthineers .. Similar Patient Search Web Service Q ? to a radiologist reading complex chest CT images. Input ROIs Tags : acute r chronic bilateral Ir basal infectious smoking common very rare Hide ROIS Desquamative Interstitial Pneumonia (DIP) |chronic bilateral basal smoking • It provides reference cases with visually similar example Frosted-glass opacities in smokers. Thieme Basal and subpleural changes are somewhat more common (60%). images from a cloud database with corresponding · Frosted-glass opacities may be diffuse or patchy. There may be occasional small cysts and emphysematous bullae. . Fibrosing changes are rare and when they do occur mild. diagnosis and relevant textbook content from Thieme. Non-Specific Interstitial Pneumonia (NSIP) |chronic bilateral basal Fine homogeneous reticulations (chronic fibrosing type) and/or frosted- What is new in SPS Web Service VA40? glass opacities (cellular acute type). Thieme · Traction bronchiectasis and volume reduction. · No dominant honeycomb patterns. In this new version of SPS, the annotations drawn by you . Predominantly basal. 3 and drawn in the reference images are displayed, allowing 1 You can draw additional ROIs to Scleroderma-related NSIP chronic bilateral basal supplement your you to better understand why a certain disease is included search Fine homogeneous reticulations (chronic fibrosing type) and/or frosted- glass opacities (cellular acute type). nieme · Traction bronchiectasis and volume reduction. as a result. No dominant honeycomb patterns. · Predominantly basal. A button is available to hide the annotations in the upper right area of the SPS Web Services page. 35 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Similar Patient Search Web Services (2/2) SIEMENS Healthineers CT Lung Assistant - DummyPatName! (1/1/1960) O x SIEMENS Healthineers ... Similar Patient Search Web Service Q ? Hide ROIs button Input ROIs Tags acute IF chronic bilateral IF basal infectious smoking common very rare Hide ROIS Allows you to hide the annotations Desquamative Interstitial Pneumonia (DIP) chronic bilateral basal smoking in the results and details pages. Frosted-glass opacities in smokers. Thieme Basal and subpleural changes are somewhat more common (60%). 1 Frosted-glass opacities may be diffuse or patchy. There may be occasional small cysts and emphysematous bullae. Fibrosing changes are rare and when they do occur mild. O Non-Specific Interstitial Pneumonia (NSIP) chronic bilateral basal 2 Fine homogeneous reticulations (chronic fibrosing type) and/or frosted- mieme Annotations .......... glass opacities (cellular acute type). ... Traction Bronchieciasis and volume reduction. . No dominant honeycomb patterns. Allows you to see how the expert Predominantly basal. radiologists have drawn the ROIs 3 O. 1 You can draw and understand why a certain result additional ROIs to Scleroderma-related NSIP chronic bilateral basal has been included. supplement your search Fine homogeneous reticulations (chronic fibrosing type) and/or frosted- glass opacities (cellular acute type). nieme Traction bronchiectasis and volume reduction. No dominant honeycomb patterns. Predominantly basal. 36 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers syngo.via CT VB70 What’s New Job Aid Cinematic Insight MM Reading CT Features Cinematic Insight is not available to USA and its future availability cannot be guaranteed. 37 Cinematic Insight is not available for several other countries due to Regulatory reasons and its future availability cannot be guaranteed. Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Cinematic Insight* SIEMENS Healthineers • The Cinematic Insight tool provides AI-supported Cinematic Insight ? X high-quality visualization of anatomical structures Templates Organs for patient and scientific communication. The Cinematic Insight tool can be invoked via the Abdomen_Overview Bone Lung_Airways • bottom right context menu (visible only for VRT and cVRT filters) or via Tool Gallery (2). Lung_Overview Cardiac RibCage Brain Lower_Abdomen Thorax_Overview Auto Views 2 VRT Gallery Display Types Reset Preset HD 2D MPR Thick MPRIMPR MIP MinIP Thin VRT Cinemat. VRT Reset Cinematic VRT Gallery Preset Insight Cinematic Insight 1 * Powered by Medical Device Syngo Carbon Clinicals 38 Cinematic Insight is not available to USA and its future availability cannot be guaranteed. Effective Date: 28 Sep 2022|HOOD05162003304980 Cinematic Insight is not available for several other countries due to Regulatory reasons and its future availability cannot be guaranteed. Unrestricted © Siemens Healthineers, 2022 Cinematic Insight – SIEMENS Healthineers Templates • The Templates allow you to display meaningful Cinematic Insight ? X cinematic renderings, by using preconfigured visualizations. Templates Organs • The templates define how the anatomy is visualized. Abdomen_Overview Bone Lung_Airways • Some of the parameters defined in the templates are: • the lighting, • which segmentation algorithm is used, Lung_Overview Cardiac RibCage • how the segmented objects are sorted, • etc. Brain Lower_Abdomen Thorax_Overview Cinematic Insight is not available to USA and its future availability cannot be guaranteed. 39 Cinematic Insight is not available for several other countries due to Regulatory reasons and its future availability cannot be guaranteed. Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 Cinematic Insight – SIEMENS Healthineers Organs • One of the most common use cases in Cinematic Cinematic Insight ? x Rendering is that you want to hide a specific object completely. Or you want to hide everything except Templates Organs Head one object. Brain You can Hide/Show objects interactively using the Thorax • Left Lung eye button in the Organs tab. O Right Lung O Aorta Heart Rihrana Not all organs were segmented Cinematic Insight is not available to USA and its future availability cannot be guaranteed. 40 Cinematic Insight is not available for several other countries due to Regulatory reasons and its future availability cannot be guaranteed. Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 41 Effective Date: 28 Sep 2022|HOOD05162003304980 Unrestricted © Siemens Healthineers, 2022

  • delta training
  • CT syngo via
  • whats new training
  • olt