
POCcelerator™ Client View and Filter Patient Results Job Aid
This job aid provides instructions to view and filter patient results from the POCcelerator™ Client Result Monitor.
POCcelerator™ Client – SIEMENS Healthineers View and Filter Patient Results Job Aid POC 1 ™ - PCC_Demo_English - X File atient results Setup Extra Info Filter Patient Results via the Data Record Filter Result Monitor |QC Monitor |Process Monitor EQA Monitor Detail fields Error log Patient Ward Order number Hans Meyer Elektrophys Ambulanz 523533766 Select Result Monitor Transfer time Model Device name 1. 22/01/2018 15:08:11 Bayer Lab0405 RapidLab 405 - Chest-Pain-Unit BGA Collection time User comments 2. Select the Filter data records button • Or select Patient results > Filter in the menu bar 2 Data received during recent 180 day(s) 3. To view erroneous patient measurements, change the filter Data record 1 of 17.589 settings to State, equal, Error Meas. time User Case number Analyte Value Unit Source Flag|LIS transmit time State Cmt. 22/01/2018 15:09:59 000999999999 BE -17.3 mmoVL A 22/01/2018 15:08:35 LIS transmission ok 22/01/2018 15:09:59 000999999999 Ca++ 0.99 mmol/L A 22/01/2018 15:08:35 LIS transmission ok • Additional filters can be added by selecting the + button 22/01/2018 15:09:59 000999999999 CI- 114 mmol/L A 22/01/2018 15:08:35 LIS transmission ok 22/01/2018 15:09:59 00104/2018 15:08:35 LIS transmission ok 4. Select Ok 22/01/2018 15:09:59 Filter data - 18 15:08:35 LIS transmission ok X 22/01/2018 15:09:59 18 15:08:35 LIS transmission ok 5. Data filter is active when the Filter data records button turns 22/01/2018 15:09:59 3 Query: 18 15:08:35 LIS transmission ok 22/01/2018 15:09:59 + |State equal Error 18 15:08:35 LIS transmission ok yellow 22/01/2018 15:09:59 18 15:08:35 LIS transmission ok 22/01/2018 15:09:59 18 15:08:35 LIS transmission ok 6. Highlight a result in the result table to display the 22/01/2018 15:09:50 18 15:10:55 LIS transmission ok 22/01/2018 15:09:50 18 15:10:54 LIS transmission ok corresponding errors in the error log 22/01/2018 15:09:50 18 15:10:55 LIS transmission ok 22/01/2018 15:09:50 18 15:10:55 LIS transmission ok 7. Erroneous patient measurements can be edited by utilizing 22/01/2018 15:09:50 10:55 LIS transmission ok 22/01/2018 15:09:50 Accept Ok 4 2:55 LIS transmission ok the patient record validation window or the error log 22/01/2018 15:09:50 Error override ... 22/01/2018 15:09:50 000526176723 Methb 0.6 % A 22/01/2018 15:10:55 LIS transmission ok 8. To view or change your filter settings, right click on the Filter 22/01/2018 15:09:50 000526176723 Na+ 145.8 mmol/L 22/01/2018 15:10:56 LIS transmission ok 22/01/2018 15:09:50 000526176723 pCO2 57.0 mmHg 22/01/2018 15:10:56 LIS transmission ok data records button 22/01/2018 15:09:50 000526176723 PH 7.243 A 22/01/2018 15:10:56 LIS transmission ok 22/01/2018 15:09:50 000526176723 p02 114.0 mmHg A 22/01/2018 15:10:56 LIS transmission ok To remove the filter, re-select the Filter data records 22/01/2018 15:09:50 000526176723 s02 • 97.6 % A 22/01/2018 15:10:56 LIS transmission ok 22/01/2018 15:09:50 000526176723 tHbBG 9.0 g/dl A 22/01/2018 15:10:57 LIS transmission ok button 22/01/2018 15:08:24 aaa bbb (Wills) 000525216039 HCT 1.35 VI 22/01/2018 15:08:34 LIS transmission ok QC violations 6 0 Conworx Conworx (1000) Note: Depending on the type of data record, different comparative variables are available. If multiple filter 1 criteria are selected, only data records that fit to all filter Effective Date: 20 Apr 2022| HOOD05162003271046 criteria are shown. Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. POCcelerator and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. All other trademarks are the property of their respective owners. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 2 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022
- poccelerator
- client
- result monitor
- filter