POCcelerator™ Client Create Comments Job Aid
This job aid provides instructions to create lab, user, and conclusion comments from POCcelerator™ Client Setup.
POCcelerator™ Client – SIEMENS Healthineers Create Comments Job Aid Create Lab Comments Comments are divided into lab, user and conclusion Fac Comments for POCT coordinator (central lab.) O × comments. Navigate Edit • Once created, comments are available as templates and can be edited at any time Lab comment New data record 2 • Edits only apply to future use of the templates Edit data record • Comments previously assigned to a QC result will not be overwritten when the Lab comment, used as a Comment code Copy data record template, is changed afterwards by editing 3 Delete data record Can be used for automatic insert Accept 4 Lab Comments can be assigned to a QC measurement in the QC Monitor screen. No Cancel 1. In the menu bar, select Setup > Comments > Lab Filter comments Unlock measuring method for patient results 2. Select New data record 3. Define the lab comment 4. Select Accept No. of data records 3 1 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022 POCcelerator™ Client – SIEMENS Healthineers Create Comments Job Aid Create User Comments If a device measures and handles QC violations internally, Poc User comments - × the device user may have to enter a comment for Navigate Edit violations. Comment code Electrode changed New data record 2 • Once defined, user comments can then be downloaded to the POCT-devices, if the devices support downloads Comment Electrode changed Edit data record Comments for patient measurements can also be defined Comment changes status to yellow (error from the User comments window and downloaded to the cause recognized by user) Copy data record device, if supported by the device. Assigned lab comment Delete data record 1. In the menu bar, select Setup > Comments > User 3 Comment for: QC measurements |Patient measurements Accept 4 comments 2. Select New data record Cancel Define the user comment Model assignment 3. ACI - ICU 1 (University Hospital; ICU; ICU 1) Filter 4. Select Accept A ACI - Delivery Ward (University Hospital; Gynecological; Delivery ward) ACI - VTS (University Hospital: Surgery; VTS) Note: In the user comment setup window you can manually ACI - Postnatal (University Hospital; Gynecological; Postnatal ward) ACI - ICU 1_2 (University Hospital; ICU; ICU 1] + + + + + define which device models can receive the created No. of data records CD comments via download utilizing the Model assignment button. Download of user comments must be activated in the device setup data for a model. 2 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022 POCcelerator™ Client – SIEMENS Healthineers Create Comments Job Aid Create Conclusion Comments Conclusion comments are required for archiving QC data. 1. In the menu bar, select Setup > Comments > POC Conclusion comments × Conclusion comments Navigate Edit 2. Select New data record New data record 2 3. Define the conclusion comment Comment code 4 Edit data record 4. Select Accept Comment Copy data record 3 Test Comment Delete data record Accept 4 Cancel Define as standard comment Filter No. of data records 0 3 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. POCcelerator and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. All other trademarks are the property of their respective owners. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 4 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022
- poccelerator
- client
- setup
- comment
- lab
- user
- conclusion