NAEOTOM Alpha VA50 Update Training - General Software Improvements Video - USA
Coming up in this video, we cover the general software improvements and added features of the software version VA50.
Welcome to the neo Tom Alpha software. VA. 50 update training for general software improvements and added features. Coming up in this training, we will cover the improvements to fast and care technologies as. Compared to the previous. Software version. VA40. General improvements with the VA 50 for the neatham alpha include. General image quality improvements based on customer. Feedback. Optimized quantum iterative reconstruction algorithms to boost reconstruction performance. With the upgrade to V. A50 Imar will now be available for use in reconstructions. The only difference I mar has with the neotoma alpha is that the spine implant setting is not currently available to select. As a substitute you can use selection of extremity implants or hip implants. Keep in mind that you can combine imar with higher Kev monoenergetic plus images for the optimal metal artifact reduction. You can utilize IMR on reconstructions with a maximum kernel sharpness of 56. Another new feature is the automated patient breathing instructions. The patient instructions can now have independent settings for before the scan range, after the scan range, or both. You can now separate and give breathing instructions only before the scan range or only after the scan range. This can be configured in the timing tab of the scan parameters. As you can see in the examples below, this is beneficial when there are two ranges back-to-back and when you need patients. To continue holding their breath throughout multiple. Ranges. With the update. To V A50 many protocols have been added for. Use. These include flex 4D dynamic scans. Intervention protocols if you purchased an intervention package. Child alternative protocols with quantum plus scan modes. Brain death protocol, which has a native brain scan and a CTA brain. Adult polytrauma multiphase. CTA cardiac. Stent with Ultra High RES scan modes. And finally new research and spectral protocols for a gammex, phantom and multi threshold body. New scan modes were added for use with the VA. 50 software. The first is. Thorax. Flash High res ultra scan mode. With flash, skin speeds up to a 3.2 pitch. And high res collimation of 120 by 0.2 millimeters. In this mode, all images will be T3D and no spectral reconstructions are possible. The next new scan mode is the high res ultra angio scan for the brain's neck or extremity. This is an angio scan mode with high res collimation of 120 by 0.2 millimeters. Spectral reconstructions are possible, but in standard resolution of 0.4 millimeters. It will have slower scan speeds due to the smaller collimation. The last new scan mode is a pelvis with high res ultra. This is a routine scan mode with high res collimation of 120 by 0.2 millimeters. Spectral reconstructions are possible, but in standard resolution of 0.4 millimeters. It will have slower scan speeds due to the smaller collimation. New additional organ settings for parallel ranges in Recon and go include. Oregon Region of lower extremities for foot or ankle. Both right and left are available. Also in the neck region for carotid bifurcation right and left. There are two new features in C view and go. Single CT Dental is now available. It supports pre surgical planning for dental operations by reformatting curved, panoramic and paraxial views along the jawbone. It also supports the definition of the mandibular canal. The average plugin from single via VB 60 is also now available in C view and go. It allows the fusion of two DICOM images. On a. Pixel by. Pixel basis and can be used for tibial, tubercle and trochlear. Groove TTG. Measurements. The protocol description has been split into. A customizable and changeable protocol description. And fixed examination information. The scan modes, decision trees, contrast protocols and possible applications are all listed in the fixed examination information. The Recon time has been improved with V A50. VBA50 includes a faster ICS computer along with optimizations to the reconstruction algorithms. With this. Upgrade. The reconstruction performance with VA. 50 could be. Improved considerably.
0.25 0.27 2.27 2.00 11 2.35 10 21.8 30 15 35 2.2 20 3.7 SIEMENS . Healthineers NAEOTOM Alpha VA50 Update Training General Software Improvements HOOD05162003279728 Unrestricted @ Siemens Healthineers, 2022 the VA Update Training Coming up in this Training: · General Software Improvements and Added Features Introduction to the Video NAEOTOM Alpha VA50 Update Training VA50 General Software Improvements General Improvements included in VA50 for the NAEOTOM Alpha · General image quality improvements based on customer feedback. · Optimized Quantum Iterative Reconstruction (QIR) algorithms to boost reconstruction performance. FAST / CARE Technologies iMAR (iterative Metal Artifact Reduction)* iMAR Reconstructions · iMAR reconstructions will be available in VA50. Note: Spine implant selection not available. You can use selection of Extremity Implants or Hip Implants in substitute. You can combine iMAR with Spectral Recon Monoenergetic Plus images for the optimal metal artifact reduction You can utilize iMAR with a maximum kernel sharpness of 56. Sn140 80 keV 0.6mm Br40 without iMAR Sn140 110 keV 0.6mm Br40 with iMAR RP *The exact amount of metal artifact reduction and the corresponding improvement in image quality achievable depends on composition and size of the metal part within the object, the patient's size, anatomical location, and clinical practice. iMAR reconstructions should be performed and evaluated in combination with standard reconstructions. iMAR can be combined with TwinSpiral Dual Energy acquisition. RPH AR Advanced Breath Hold Settings Automated Patient Instruction: Independent setting of patient instructions before each scan, after each scan as well as before and after You can now separate and give breathing instructions just before the scan range or only after the scan range. This is beneficial when there are two ranges back-to-back, and when you need patients to continue holding their breath throughout multiple ranges. Scan Favorites General Scan Dose Timing Config Physio Scan Contrast Scan/Recon Rot. Scan Time Exam Time Cycle Patient Instruction Instruction Post Instruction Post Bolus Time [s] [s] Command Delay [s] Delay (BT) [s] Valve Cardiac Before Scan After Scan Before Scan; After Scan 2.7s Confic FAST / CARE Technologies provements breath throughout multiple ranges.hased an intervention package) Child Alt Protocols with Quantumplus scan modes Brain Death Protocol (Native & CTA Brain) Adult Poly Trauma Multi Phase CTA Cardiac Sten New research an Protocols New Protocols Added in VA50 Flex 4D Dynamic scans Intervention Protocols (if you purchased an intervention package) CTA Cardiac Stent with UHR scan mode New research and spectral protocols (Gammex phantom, multi threshold body) Scan Modes New Scan Modes Added in VA50 Thorax [factory] Protocol Description -Indications: masses, tumor, metastases, lymphom nodes, tuberculosis, empyema, infection, early vis Thorax Flash Highresultra Scan Favorites / Flash scan speeds up to 3.2 pitch High-res collimation 120x0.2mm Recon Favorites General Recon Recon&GO Image Impression Recon Box · All images T3D, No spectral reconstructions possible Decision Tre Topogram ScanplanningTopoAdultQuantumSn Thorax RoutineSpiralAdultThoraxQuantumplusXcare RoutineFlashSpiralAdultThoraxHigh resultraQuantumplus New Scan Modes in VA50 Protocol Description -Indications: masses, tumor, metastases, lymphom BraFoot right and left mity CTA with Highresultra Scan ModeTiming Premonitoring Monitoring . Slower scan speeds due to smaller collimation RoutineSpiralAdultAngioExtremitiesHighresultraQuantumplus · Angio scan modes with high-res collimation Decision T Spectral reconstructions possible in standard resolution (0.4mm) CTA Extremity RoutineSpiralAdultAngioExtremitiesQuantu Pelvis with Highresultra . Routine scan modes with high-res collimation Pelvis [factory] (Adult) Pelvis RoutineSpiralAdultPelvisQuantumplus RoutineSpiralAdultPelvisHighresultraQuantumplus Acc Recon&GO Technologies Recon&GOVlodes in VA50 New organ settings for Parallel Ranges Inline Results Orgar Viewing Direction Ankle 3.00 Qr40 Q3 ax DE Parallel Ranges No Organ Feet to He ... Knee Joint Femur L Knee Joint R Knee Joint Tibia R Ankle L Foot R Foot L Whole Body · Carotid bifurcation right and left Reso Pelvis [factory Carotid 3.00 Qr40 Q3 ax Head Temporal Bone R Routinesp Head & Neck A. Carotis COW A. Carotis Bifurcation L · Foot right and left · Ankle right and left Ankle R High Head Sinus Foot Spine Recon&GO Technologies Technologies Auto as definition of the mandibular canal. Foot R nergy No Organ Feet to He .. Applications & View&GO Technologies Auto Tasking syngo.CT Dental: · This application supports pre-surgical planning for dental operations by Local Printing Applicati ... reformatting curved panoramic and paraxial views along the jaw-bone as well Off None CT Neuro Perfusion CT CaScoring CT Dental CT Dual Energy Average plugin: · Allows fusion of two DICOM images on a pixel-by-pixel basison Used for tibial tubercle-trochlear groove (TT-TG) measurementsoryl -Indications: stroke, hemorrhage, cerebral atrophy, hydrocephalus, inflammation, wo CM Examination Information Decision Trees -Scan Modes: RoutineSpiralAdultHeadQuantumplus -Decision Trees: Brain contrast medium necessary Contrast Protocols [factory] Possible Applications Protocol: Brain Multi Phase [factory] -Indications: stroke, tumors, cerebral atrophy, hydrocephalus, inflammation,w and wo CM Non Contrast Brain Venous Phase Brain eSpiralAdultHeadQuantumplus Protocol Description split into Protocol: Brain [factory] · A changeable Protocol Description . A fixed Examination Information with Brain -Contrast Protocol: Brain [factory] Recon Time Improvement between VA40 & VA50 The upgrade to VA50 includes a faster ICS computer along with optimizations to the reconstruction algorithms. With this upgrade, we have been able to improve the reconstruction performance in VA50. Takeaways: · Reconstruction time performance improvements. · System showed robustness against higher patient frequencies. · Bigger hard drive installed for greater storage capacity. Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthcare GmbH 2022 SIEMENS
- ct
- va50
- update
- general
- improvements
- naeotom
- neotom
- alpha
- aphla